型號(hào):紅外氣體分析儀ZPA
更新時(shí)間:2024-04-13
瀏覽次數(shù):1286
公司地址:銷售地址:陜西省西安市高新區(qū)丈八五路高科尚都摩卡7幢1單元6層10609號(hào)房 工廠地址:陜西省西咸新區(qū)統(tǒng)一西路眾泰電力設(shè)備廠區(qū)1號(hào)廠房
![]()
任經(jīng)理(女士) 銷售主管
我們期待著以我們靈活的營銷機(jī)制、精良的裝置設(shè)備、穩(wěn)定的產(chǎn)品性能、優(yōu)質(zhì)的技術(shù)服務(wù),與您攜手共同創(chuàng)造儀表業(yè)輝煌的明天!
Xi 'an Saipu Automation Technology
Co., Ltd. was established in Xi'an High-tech Zone. It is a comprehensive
high-tech enterprise integrating scientific research, production,
manufacturing, marketing and engineering services of industrial automation
products instrumentation. At the same time, it relies on the Institute of
Electro
The company is engaged in gas analysis instruments, flow meters,
liquid level instruments, pressure instrument series of products research and
development, design, manufacturing one of the brand manufacturers. A rich range
of products has been formed: gas analysis instruments(chemistry, magnetooxygen,
infrared, thermal conductivity, etc.) dew point microwater analysis(Visala, Michal
Michelle, United States Philmetrix, etc.) Fixed and portable gas detection
alarms(Honeywell, Huarui, etc.) gas o
The game spectrum instrument is ba
We look forward to our flexible marketing mechanism, sophisticated equipment,
stable product performance, quality technical services, and you work together
to create a brilliant instrument industry tomorrow!
| 測量原理 |
NO,SO2,CO,CO2,CH4:非分散型紅外線吸收法(單光束) |
|
|---|---|---|
| 測量成分及測量范圍 |
NO:0~200ppm···5000ppm |
|
| 測量量程 | 1組分多2量程 | |
| 重復(fù)性 | ±0.5%FS | |
| 線性 | ±1%FS | |
| 零點(diǎn)漂移 |
±2%FS/周 (0~500ppm的NO,SO2為±2%FS/天) |
|
| 滿量程漂移 | ±2%FS/周 | |
| 響應(yīng)時(shí)間(90%以內(nèi)) | 10~30秒以內(nèi)(根據(jù)測量范圍) | |
| 模擬輸出信號(hào) | DC4~20mA或DC0~1V | |
| 測量值顯示 |
帶背景燈LCD(日語,英語或中文:根據(jù)) 各成分的瞬時(shí)值,O2換算瞬時(shí)值,O2換算平均值,O2平均值 |
|
| 量程切換 | 通過按鍵操作可進(jìn)行手動(dòng)量程切換、自動(dòng)量程切換,外部接點(diǎn)輸入可進(jìn)行遠(yuǎn)程切換(選配)。 | |
| 外部接點(diǎn)輸入(選配) |
電壓輸入接點(diǎn)(供壓DC12~24V,zui大電流15mA) 遠(yuǎn)程量程切換,自動(dòng)校正遠(yuǎn)程啟動(dòng),遠(yuǎn)程輸出保持,平均值復(fù)位 |
|
| 接點(diǎn)輸出(選配) |
1c繼電器接點(diǎn)(接點(diǎn)容量 DC24V/1A 阻性負(fù)載) 儀表異常,校正異常,量程識(shí)別,自動(dòng)校正中,自動(dòng)校正用電磁閥驅(qū)動(dòng), 上下限報(bào)警,CO濃度峰值報(bào)警 |
|
| 氣壓干擾補(bǔ)償(選配) | 根據(jù)內(nèi)置 | |
| 標(biāo)準(zhǔn)功能 | 輸出信號(hào)保持,手動(dòng)/自動(dòng)量程切換 | |
| 選配功能 |
自動(dòng)校正,自動(dòng)校正遠(yuǎn)程啟動(dòng),遠(yuǎn)程輸出保持,量程識(shí)別接點(diǎn)輸出, 上下限警報(bào)輸出,O2換算值輸出,O2換算平均值輸出,平均值復(fù)位接點(diǎn)輸出, CO濃度峰值警報(bào)接點(diǎn)輸出 |
|
| 通信功能(選配) | RS-485(Modbus)(9針D-sub輸出) 半雙工位串行,起止同步式 | |
| 氣體出入口尺寸 | Rc1/4 或 NPT1/4內(nèi)螺紋 | |
| 吹掃氣體流量 | 1L/min(根據(jù)需要) | |
| 周邊溫度濕度 | -20~60℃ 90%以下(無結(jié)露) | |
| 電源電壓 | AC100V~240V 50/60Hz | |
| 額定功率 | 約100VA | |
| 外形尺寸 | 133(H)×483(W)×382(D)mm | |
| 重量 | 約10kg | |
| 適用認(rèn)證 | CE認(rèn)證 | |
| 被測氣體條件 | 流量 | 0.5L / min ±0.2L / min |
| 溫度 | 0 ~ 50℃ | |
| 壓力 | 10kPa以下 | |
| 粉塵 | 0.3μm以下的顆粒:100μg / Nm3以下 | |
| 氣霧 | 無 | |
| 水分 |
室溫飽和范圍內(nèi)(無結(jié)露) 但是當(dāng)NO,SO2,CO分析儀測量濃度為0 ~ 200ppm時(shí),不能超過2℃飽和(無結(jié)露) |
|
| 腐蝕性成分 | HCL 1ppm以下 | |